Skip to content

In roofer review

Storm & insurance job line-item checklist

The line items a storm claim scope leaves off — the ones that are money you do not get paid. Every line is going past a working roofer before it goes live here, because on a supplement a wrong line costs you in both directions.

Why a roofer checks it first

Every other tool here is arithmetic: a number goes in, a number comes out, and you can check it against your own takeoff in a minute. This one is different. A checklist used on a claim job is advice about what to put on a supplement, and a wrong line costs real money in both directions — an item left off is money a contractor does not get paid, and an item that does not belong is a claim problem with their carrier.

We drafted it from common storm-claim scope categories. That is not the same as knowing it is right, and nobody who has argued a supplement with an adjuster has read it yet. So it waits.

Draft. A working roofer has not checked these lines yet, so do not rely on them on a live claim. Read it, and tell us what is missing.

Be the roofer who reviews it

If you work storm and insurance jobs, you already know what the draft below is missing. Tell us what is wrong with it and the corrected list goes live with your name on it, or without it — your choice. There is nothing to sign up for and no newsletter at the end of it.

The draft is 31 items across 9 categories, 23 of them flagged as commonly missed. A read-through takes about ten minutes.

The unreviewed draft

Do not rely on this. It is printed here so the draft can be read and corrected, not so it can be used on a job. It is not legal or claims advice, and nothing here has been checked against how a carrier in your state actually scopes. Items marked commonly missed are the draft’s own guess at what gets left off a first scope — that guess is exactly what needs checking.

Tear-off and disposal

  • Remove existing roofing, per layerper square

    Count the layers. A second layer is a separate line, not a multiplier someone remembers later.

  • Dumpster / haul-awayper job

    Separate from tear-off labor on most scopes.

  • Decking replacementper squarecommonly missed

    Unknown until the roof is open. Note it as a contingency with a unit price agreed up front.

Roofing

  • Shingles, including wasteper square

    State the waste allowance on the line so it is not argued later.

  • Underlaymentper square

    Synthetic is not the same price as felt. Say which.

  • Ice-and-water shieldper squarecommonly missed

    Required by code in many jurisdictions and often omitted from a first scope.

  • Starter courseper lineal footcommonly missed

    A separate manufactured product, not cut-up field shingles.

  • Hip and ridge capper lineal footcommonly missed

    Priced per lineal foot and frequently left off.

Flashing

  • Drip edge, eaves and rakesper lineal footcommonly missed

    Both edges. Rake drip edge is the one that gets missed.

  • Step flashing at wallsper lineal footcommonly missed

    Reusing old step flashing is not a repair.

  • Counter flashingper lineal footcommonly missed

    Masonry walls and chimneys.

  • Valley metalper lineal foot

    Open valleys only; say which detail is being used.

  • Pipe jacks / bootseachcommonly missed

    Count them on the roof. Each one is a line.

  • Chimney flashing and cricketeachcommonly missed

    A cricket is a separate item from the flashing.

Ventilation

  • Ridge ventper lineal foot

    Replaced, not reused, on a tear-off.

  • Box / static ventseach

    Count them.

  • Convert static vents to ridge ventper jobcommonly missed

    A change in the system, not a swap. Needs its own line and the homeowner's agreement.

  • Soffit / edge intake ventper lineal footcommonly missed

    Exhaust without intake does not ventilate. Often missing entirely.

Accessories

  • Detach and reset satellite disheachcommonly missed

    Detach-and-reset is a standard line item.

  • Detach and reset solar panelsper jobcommonly missed

    Needs a specialist and is expensive. Never absorb it.

  • Skylight flashing kit or replacementeachcommonly missed

    A re-roof around an old skylight is a callback waiting to happen.

Gutters and downspouts

  • Gutters and downspoutsper lineal footcommonly missed

    Hail-dented gutters are part of the same storm.

  • Gutter guardsper lineal footcommonly missed

    Separate from the gutter line.

Other exterior

  • Fascia and wrapper lineal footcommonly missed

    Damaged on removal more often than anyone admits.

  • Siding, soffit, wrapsper squarecommonly missed

    Hail that hit the roof hit the elevations too. Inspect all four.

  • Window screens and AC condenser finseachcommonly missed

    Cheap, routinely covered, and almost always forgotten.

Interior

  • Interior water damage: drywall, paint, insulationper jobcommonly missed

    Needs photographs taken before anything is touched.

Labor and other

  • Steep-pitch chargeper squarecommonly missed

    Priced per square above a stated pitch. State the pitch.

  • Two-story / height chargeper squarecommonly missed

    A separate line from the steep charge.

  • Permitper job

    A pass-through cost, and still a line.

  • Fall protection / OSHA complianceper jobcommonly missed

    A real cost of doing the job legally.

When the list has been corrected, this page becomes the working checklist: the same items, grouped the same way, with a tick box against each one and the ticked lines copyable into a supplement.

Storm & insurance job line-item checklist · RoofParrot